Product description

Eaton Electric is a company that manufactures modern overcurrent circuit breakers in a wide range of current ratings. They are used in residential and public buildings, as well as in industry.They protect electrical installations from the effects of short circuits and overloads. These products have a convenient elevator terminal system, which ensures that the connecting wires are firmly attached. They are tailored for quick installation on a standard TS35 mm rail. Busbars are also available to connect circuit breakers and residual current switches with different pole configurations. All circuit breakers offered by the company have extensive accessories, i.e. auxiliary contacts, triggers, as well as enclosures.

Residual current circuit breakers belong to the modular apparatus, whose task is to protect installations and electrical equipment from the dangerous effects of overloads. The circuit breaker is manufactured from non-flammable plastic - so it remains resistant to the harmful effects of high temperatures during failure. The circuit breaker is used in the creation of electrical installations in a house or apartment. The device also provides fire protection. The problem is informed by a large function key which automatically switches to the failure mode.Thus, we are able to prevent the spread of the failure.

Technical data:

  • Number of poles 1P + N
  • Number of modules 18mm 2
  • Characteristics B
  • Design (type of circuit breaker) AC (sinusoidal current)
  • Rated current In 16 A
  • Rated residual current IΔn 30 mA
  • Rated residual non-trip current IΔno 15 mA
  • Short-circuit resistance Inc 6000 A
  • Rated switching voltage Ue (AC) 230 V
  • Rated frequency 50 Hz
  • Rated surge voltage Uimp 4 kV
  • Rated insulation voltage Ui 440 V
  • Tripping time without delay
  • Electrical strength (number of cycles) 4,000
  • Mechanical endurance (number of cycles) 20,000
  • Mounting 35 mm rail (TH35/DIN)
  • Connection method rail/wind terminal
  • Max. cross-section of connection wires 25 mm²
  • Degree of protection IP40
  • Device protrusion 60 mm (69.5 mm with lever)
  • Dimensions (W × H × D) 35×80×74.5 mm
  • IEC/EN 61009 standards